Mahr Inc. Product Line
Mahr Inc.

844D - Plug Gages

844 D Plug Gages - The new Dimentron

844D - Plug Gages

Bore measurement with a guide cylinder

The Marameter 844 D indicating plug gage was previously sold as the Dimentron plug. It is a two-point bore gage: two opposed carbide contacts are spring-loaded outward, and a carbide pin carries their radial movement to a dial comparator or digital indicator. The reading is the bore's deviation from the setting ring used to zero the gage.

A two-point gage reads the true diameter only when its contacts sit straight across the middle of the bore and square to it. Off to one side, the contacts measure a line that misses the center, which is shorter than the diameter, so the gage reads small. Tipped, they measure on a slant from wall to wall, which is longer than the diameter, so the gage reads large.

A split-ball gage centers itself side to side but can still tip, so the operator rocks it and takes the smallest reading, the reversal point. The 844 D handles both errors mechanically. Its guide cylinder is ground just under the bore size, so once it is in the hole it can neither slide sideways nor tip. There is no reversal point to find: the first reading is the reading.

  • Measuring force comes from a built-in spring, so it does not vary with the operator.
  • Diameter, roundness and conicity: one reading gives the diameter. Rotating the gage shows roundness deviation, and readings at several depths show conicity.
  • Published performance: repeatability 1 µm (≈ .00004"); linearity deviation 1 % (min. 1 µm), 1.5 % on the DS types.
Marameter 844 D indicating plug gage head showing the guide cylinder and a carbide measuring contact
844 D measuring head: the ground guide cylinder locates the gage in the bore; the carbide contact in the cylinder wall senses the diameter.
Three diagrams: contacts straight across the middle read the true diameter; contacts off to one side span a shorter line and read small; a tipped gage spans a longer slanted line and reads large
The two ways a two-point reading goes wrong. Off-center reads small; tipped reads large. The 844 D guide cylinder prevents both.

When to choose a plug gage

A plug gage suits the same bore checked over and over: production lots, in-process checks at the machine, or incoming inspection of one part number. Each gage is made to one nominal size, and no rocking technique is involved, so different operators get the same reading quickly. The trade-off is that a gage serves only that size. Many different bore sizes in small quantities mean many gages.

Your applicationStart with
One bore size, tolerance 10 µm (≈ .0004") or wider, open bore844 D
Tolerance under 10 µm844 D-HR (tighter guide-cylinder fit)
Tolerance zone wider than the 0.2 mm span844 D-M (0.4 or 0.6 mm span)
Through hole, or a bore in sheet or a thin wall844 DR
Diameter near the bottom of a blind hole844 DS; 844 DS-F for very short blind holes
Diameter at a specific depth on the drawing844 D-FD, or a depth stop on the standard gage
Soft or easily marked surfaces (aluminum, non-ferrous)-C, -R or -D contacts (chrome, ruby, diamond)
Interrupted bore, or concern about lobed (out-of-round) form844 D-3 three-point gage, Ø 4–100 mm
Bores under Ø 2 mm, or many small sizes at low volume844 K split-ball probe set (Ø 0.95–20.6 mm)

A two-point gage reads diameter across opposite contacts, so a bore with odd-numbered lobes (three, five) can read round. If that form error matters to the part, plan for the three-point 844 D-3 rather than relying on rotating a two-point gage. The 844 D covers Ø 2–200 mm; larger bores fall outside this family.

Three basic types by bore geometry

Every 844 D is made to one nominal bore size, with a measuring span of 0.2 mm (≈ .008"), or 0.15 mm below Ø 3 mm. Each has a hard-chrome guide cylinder and carbide measuring contacts. The types differ in where the contacts sit, measured as the distance e from the front face, and in how much guide length supports the gage.

Standard
844 D standard plug gage in a bore

844 D

Ø 2–200 mm (≈ .079–7.87"). e = 1.5–4 mm. For fast checks of precise bores in general work.

Choose it when the bore is open and the characteristic is not right at an edge or bottom.

Through holes
844 DR plug gage in a thin sheet and in a through hole

844 DR

Ø 4–200 mm. e = 6–10 mm. An extended guide cylinder runs past the contacts, so the gage stays aligned in through holes and in parts thinner than the guide.

Choose it when the bore is in sheet or a thin wall, or must be measured from the edge of a through hole.

Blind holes
844 DS plug gage measuring near the bottom of a blind hole

844 DS

Ø 2–200 mm. e = 0.7–1.2 mm. The contacts sit close to the front face. Linearity deviation is 1.5 % (min. 1 µm).

Choose it when the diameter must be checked close to the bottom of a blind hole.

Variants by measuring problem

Variants change one property of the basic type: the contact material, the contact position, the measuring span, the guide-cylinder fit or the number of contacts.

VariantWhat changesTypes and rangeUse it for
-CHard-chrome contactsD, DR, DS: 8–200 mmSensitive non-ferrous and aluminum surfaces
-RRuby-tipped contactsD, DS: 3–200 mm; DR: 4–200 mmVery sensitive non-ferrous and aluminum surfaces
-DDiamond-tipped contactsD, DR: 8–200 mmVery sensitive surfaces of soft non-ferrous metals and aluminum
-FDFront distance e to customer specificationD: 2–200 mm; DR: 4–200 mmMeasuring closer to the bottom, or at a defined position
-MMeasuring span 0.4 mm (Ø 3–7) or 0.6 mm (Ø >7)D, DS: 3–200 mm; DR: 4–200 mmWider tolerance zones
-HRGuide cylinder held to a tighter toleranceD, DS: 3–200 mm; DR: 4–200 mmTolerance zones under 10 µm
DS-FFront chamfer only, no centering grooveDS: 2–200 mmVery short blind holes
-3Three contacts at 120°; linearity deviation 2 % (min. 1 µm)D, DR: 4–100 mmInterrupted bores and polygonal (odd-lobed) form errors
Cross-section of 844 D-3 with three contacts at 120 degrees
844 D-3. Three contacts at 120° pick up odd-lobed form that a two-point gage reads as round, and bridge interruptions in the bore wall.
844 D-FD showing the front distance e from face to contact
844 D-FD. Front distance e is made to order, so the contacts measure at the depth the drawing calls out.

Tolerance under 10 µm? Guide-cylinder clearance is the limit

Mahr rates the standard 844 D for tolerance zones of 10 µm (≈ .0004") and more. Against the 1 µm repeatability, that is a 10:1 ratio. The guide cylinder has to clear the bore, and the remaining gap lets the gage shift radially and axially. The HR version is ground closer to nominal, which cuts that gap by 10 µm at every size:

Bore ØGuide cylinder, standardGuide cylinder, HR
3–20 mm−15 / −25 µm−5 / −15 µm
>20–60 mm−20 / −30 µm−10 / −20 µm
>60–130 mm−25 / −35 µm−15 / −25 µm
>130–200 mm−35 / −45 µm−25 / −35 µm

For example, an H5 bore at Ø 25 mm has a 9 µm (≈ .00035") tolerance under ISO 286, which puts it in the HR range. An H7 bore at Ø 40 mm (25 µm, ≈ .001") is well within the standard gage's range.

Specifying a gage and building the setup

Because each 844 D is made to one bore, an order states three things: the order number (which fixes the type, variant and size band), the nominal bore diameter, and the bore tolerance as an ISO fit or numeric limits. For example, an 844 D for Ø 34.5 mm H8, or an 844 DR for Ø 74.55 mm +0.05 / −0.03 mm.

The plug gage screws onto a holder that carries the indicator. Extensions, a 90° attachment and depth stops thread in between. Mahr shows three typical builds:

TaskStack, indicator to bore
Standard checkComparator, 844 Dg holder, plug gage
Defined measuring depthComparator, 844 Dg holder, 844 Dv extension, 844 Dt-3 depth stop, plug gage
Side-entry bore at a defined depthComparator, 844 Dg holder, 844 Dw 90° attachment, plug gage, 844 Dt-R stop ring

Holders, reach and measuring depth

  • 844 Dg holders take Ø 8 mm indicator shanks and M6 × 0.75 or M10 × 1 plug gages, in lengths from 109 to 249 mm.
  • 844 Dga adds a lifting lever that retracts the contacts. It eases a DS gage into a blind hole and is recommended for small, sensitive bores.
  • 844 Dg-XL is the heavy holder for plug gages from Ø 60 mm, especially on long Ø 18 mm extensions.
  • 844 Dv extensions run from 48 to 1000 mm (≈ 1.9–39.4"). 844 Dw turns the measuring axis 90° for side bores and for checks in a lathe or grinder.

Depth stops set a repeatable measuring depth and keep the gage from tilting on entry: the 844 Dt-R ring clamps on the guide cylinder (Ø 3–105 mm). The Dt-S disc (Ø 16–40 mm), Dt-B bridge (Ø 16–160 mm) and Dt-3 three-point stop (Ø 20–150 mm) clamp on the holder or extension shank.

844 Dw right angle attachment
844 Dw turns the measuring axis 90° for side-entry bores.

Setting ring and temperature

The 844 D is zeroed on a setting ring at the nominal size, so the reading is only as good as the ring. It also depends on how closely the ring and the part share a temperature. A steel ring and a steel part at the same temperature grow together, and the error largely cancels.

Aluminum does not cancel. Take an aluminum bore (≈ 23 µm/m·K) checked against a steel ring (≈ 11.5 µm/m·K), both at 25 °C instead of the 20 °C reference. At Ø 100 mm the differential growth is 11.5 µm/m·K × 0.100 m × 5 K = 5.75 µm (≈ .00023") (calculated). That is more than five times the gage's repeatability.

Set of setting rings
Setting rings define the zero at the nominal bore size.

Indicator and data path

Indicator resolution sets the smallest step you can see. It does not change the gage's 1 µm repeatability. Choose the indicator for the tolerance zone and for where the data has to go.

IndicatorResolutionRangeRole
Millimess 10020.5 µm±25 µmAnalog comparator, tight tolerance zones
Millimess 10031 µm±50 µmAnalog comparator, general use
1086 R / Ri0.5 µm12.5 mmDigital indicator for processing measured values
1086 R-HR0.1 µm12.5 mmDigital, finest display step
P2004 M + C 1200 M—±2 mm probeInductive probe and compact amplifier in the 844 Dge holder, with fine adjustment
Millimess 1003 dial comparator
Millimess comparator: shows deviation from the setting ring zero.
Mahr digital indicator
Digital indicator: displays the value and passes it on for processing.
844 Dge plug gage holder for inductive probe
844 Dge: holds an Ø 8 mm inductive probe over the plug gage for amplifier readout.

Below Ø 2 mm, or many sizes: 844 K split-ball probes

The 844 K covers Ø 0.95–20.6 mm (≈ .037–.811") with interchangeable split-ball probes on one holder. Its repeatability (1 µm) and linearity deviation (1 % min. 1 µm, 2 % on Ø 1–1.4 mm probes) match the 844 D.

The trade-off is centering. The two halves of the split ball expand equally, so the contacts center side to side and land on a diameter rather than a chord. The short ball can't hold the probe square to the bore axis, though. The operator rocks the gage through the axis, and the smallest reading, the reversal point, is the one taken square to the bore. A 1087 BR/BRi digital indicator records that minimum with its MIN function, and the 844 KM measuring stand removes the rocking step altogether.

Each probe covers a band rather than one size: 0.2 mm (Ø 1–1.4), 0.4 mm (Ø 1.75–3.75), 0.6 mm (Ø 4–9.5) or 1.2 mm (Ø 10–20). Cased sets cover the full range in five groups. The probes come in hard chrome (844 K), DLC-coated (844 KC) and blind-hole (844 KS) versions. The 844 Kgz holder takes 3/8" indicator shanks.

Split-ball bore gage rocked through the bore axis to find the minimum reading
Rocking an 844 K through the axis: the smallest reading is the reversal point and the bore diameter. The 844 D's guide cylinder makes this step unnecessary.
844 D plug gage844 K split-ball probe
Diameter range2–200 mm0.95–20.6 mm
CenteringGuide cylinder: centers and alignsSplit ball: centers side to side, not in tilt
Reversal pointNot requiredFound by rocking, or with the 844 KM stand
Range per gageOne bore size; 0.2 mm span0.2–1.2 mm band per probe
Contact surface optionsCarbide, hard chrome, ruby, diamondHard chrome, DLC
Best fitOne bore size checked in volume, independent of operator techniqueSmall bores in many sizes, one instrument across a range

Where ICS fits

Industrial Channel Solutions is a manufacturers' representative. We match your application to the right measuring tools. For Marameter plug gages, the selection depends on:

  • Diameter and tolerance: the nominal bore, the tolerance zone and the gage ratio you need (standard, HR or -M span)
  • Bore geometry: open, through, blind, short, interrupted or thin-walled, and where along the bore the characteristic sits
  • Material and finish: steel, aluminum or soft non-ferrous metals, and how sensitive the surface is
  • Access: bore depth, side bores, or checks in the machine
  • Data path: visual check, or values sent on for processing
  • Number of sizes: a dedicated 844 D per bore, or 844 K probes for small bores across many sizes

From those inputs we recommend one measuring setup: the plug gage type and variant, holder, indicator, extensions and depth stops.

Questions about 844D - Plug Gages?

Tell us about your application and we'll point you to the right solution.